Belimo R3015-2P5-S1 - 3-way characterised control ball valve

Price: zł476.90
VAT included
zł387.72 tax excluded

3-way characterised control ball valve for closed water systems. DN 15, PN 40, Rp 1/2" female thread, Kvs 2.5 m³/h.

Designed for continuous control on the water side of ventilation and heating systems. Fluid temperature: -10...120°C [14...248°F].

Product availability: Delivery in approx. 14 days
Share

Belimo R3015-2P5-S1 – 3-way control valve

Characterised control ball valve for closed water systems, designed for continuous control on the water side of ventilation and heating systems.

Key features and specifications

  • DN 15, PN 40; Rp 1/2" female thread.
  • Kvs 2.5 m³/h; flow through bypass B – AB: 70% of the Kvs value.
  • Fluid: water, water with max. 50% by volume glycol; fluid temperature -10...120°C [14...248°F].
  • Maximum differential pressure ∆pmax 350 kPa; closing pressure 1400 kPa. 200 kPa is specified to ensure quiet operation.
  • Flow characteristic A – AB: equal percentage; B – AB: linear.
  • Leakage A – AB: bubble-tight, leakage rate class A; B – AB: leakage rate class I, 1...2% of the Kvs value.
  • Nickel-plated brass body; stainless steel closing element and stem.
  • Rotary angle: 90°.

Installation notes

Permitted installation position: from vertical to horizontal relative to the axis. Do not install with the axis pointing downwards. Observe the flow direction indicated by the arrow on the body.

At fluid temperatures of -10...2°C, stem heating or a valve neck extension is recommended. The permitted fluid temperature may depend on the actuator used.

  • Brand
  • Reference
    R3015-2P5-S1
  • EAN13
    7630498107191

  • Kvs
    2.5 m³/h
  • Medium
    Water, water with up to 50% vol. glycol.
  • Pattern
    3-way
  • Fluid temperature
    -10...120°C [14...248°F]
  • Fluid temperature, note
    For medium temperatures of -10...2°C, heating the shaft or extending the valve neck is recommended. The permissible medium temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for restrictions.
  • Differential pressure
    ∆pmax 350 kPa
  • Closing pressure
    1400 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Flow characteristic
    A – AB: equal-percentage; B – AB: linear
  • Permissible leakage
    A – AB: bubble-tight, leakage class A; B – AB: leakage class I, 1...2% of Kvs value
  • Pipe connection
    Internal thread

Techniczna karta katalogowa

Download (1.2MB)

Instrukcja montażu

Download (544.39KB)

Techniczna karta katalogowa – R3..xx-S..

Download (1.2MB)

EU Declaration of Conformity – R20.. / R30.. DN 15...32

Download (130.96KB)

Environmental Declaration – R3..

Download (70.32KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...
Back to top