Belimo R3020-6P3-S2 - 3-way control valve with orifice

Price: zł534.53
VAT included
zł434.58 tax excluded

Belimo R3020-6P3-S2 is a 3-way control valve with an orifice, designed for closed water systems. DN 20, PN 40, Rp 3/4" internal thread, Kvs 6.3 m³/h.

Operates with water or water mixed with up to 50% by volume glycol at a medium temperature of -10...120°C [14...248°F].

Product availability: Delivery in approx. 14 days
Share

Belimo R3020-6P3-S2 – 3-way control valve

Control valve with a regulating orifice for water-side control in ventilation and heating systems in closed water systems. The valve is operated by a rotary actuator.

Key features and specifications

  • Connection and size: DN 20, PN 40, Rp 3/4" internal thread.
  • Kvs: 6.3 m³/h; flow through bypass B – AB: 70% of the Kvs value.
  • Medium: water, water mixed with up to 50% by volume glycol.
  • Medium temperature: -10...120°C [14...248°F].
  • Differential pressure: ∆pmax 350 kPa; closing pressure 1400 kPa. 200 kPa is specified for quiet operation.
  • Flow characteristic: A – AB: equal-percentage characteristic; B – AB: linear.
  • Tightness: A – AB: bubble-tight, leakage rate class A; B – AB: leakage rate class I, 1...2% of the Kvs value.
  • Materials: nickel-plated brass body, stainless steel closing element and stem, ETFE regulating orifice.
  • Installation: any position from vertical to horizontal relative to the axis; installation with the stem pointing downwards is not permitted.

At a medium temperature of -10...2°C, stem heating or a valve neck extension is recommended. The permissible medium temperature may depend on the actuator used; limits are given in the relevant actuator data sheets.

  • Brand
  • Reference
    R3020-6P3-S2
  • EAN13
    7630498107672

  • Kvs
    6.3 m³/h
  • Medium
    Water, water with up to 50% vol. glycol.
  • Pattern
    3-way
  • Fluid temperature
    -10...120°C [14...248°F]
  • Fluid temperature, note
    For medium temperatures of -10...2°C, heating the shaft or extending the valve neck is recommended. The permissible medium temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for restrictions.
  • Differential pressure
    ∆pmax 350 kPa
  • Closing pressure
    1400 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Flow characteristic
    A – AB: equal-percentage; B – AB: linear
  • Permissible leakage
    A – AB: bubble-tight, leakage class A; B – AB: leakage class I, 1...2% of Kvs value
  • Pipe connection
    Internal thread

Techniczna karta katalogowa

Download (1.2MB)

Instrukcja montażu

Download (544.39KB)

Techniczna karta katalogowa – R3..xx-S..

Download (1.2MB)

EU Declaration of Conformity – R20.. / R30.. DN 15...32

Download (130.96KB)

Environmental Declaration – R3..

Download (70.32KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...
Back to top