Belimo EP125F2-25+KBAC - 2-way EPIV control valve

Price: zł59,667.30
VAT included
zł48,510.00 tax excluded

2-way EPIV control valve with pressure-independent flow control and safety function. DN 125, PN 25, flanged connection, V'nom 33.3 l/s (120 m³/h).

AC/DC 24 V supply; 2...10 V modulating control and BACnet MS/TP, Modbus RTU and MP-Bus communication. The device measures flow and fluid temperature and monitors glycol concentration.

Product availability: Product unavailable
Share

Notify me when available

Interested in this product? Drop us an email and we will let you know when it's available for order.

Belimo EP125F2-25+KBAC

2-way EPIV control valve with sensor-based flow control and safety function. Designed for closed-loop water systems and water-side control in ventilation and heating systems.

Key features and specifications

  • Nominal diameter DN 125, nominal pressure PN 25, flanged connection.
  • Nominal flow V'nom 33.3 l/s (120 m³/h); V'max adjustable from 25...100% V'nom.
  • Fluid: water or water with a maximum of 60% vol. glycol; fluid temperature -10...120°C [14...250°F].
  • Differential pressure ∆pmax 350 kPa; closing pressure ∆ps 690 kPa.
  • AC/DC 24 V supply; power consumption during operation 12.1 W, in the rest position 4.1 W.
  • Modulating, communicative or hybrid control; operating range Y 2...10 V; BACnet MS/TP, Modbus RTU and MP-Bus communication.
  • Ultrasonic flow measurement, fluid temperature measurement and glycol concentration monitoring.
  • Safety function with position setting 0...100%; travel time in safety function 35 s / 90°.
  • Configuration via NFC using Belimo Assistant 2; manual adjustment by button.
  • 1 m connection cable; IEC/EN IP54 degree of protection; IEC/EN protection class III, Protective Extra-Low Voltage (PELV).

At a fluid temperature of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may depend on the actuator type.

  • Brand
  • Reference
    EP125F2-25+KBAC
  • EAN13
    7630498136924

  • Medium
    Water, water with max. 60% vol. glycol.
  • Pattern
    2-way
  • Fluid temperature
    -10...120°C [14...250°F]
  • Fluid temperature, note
    At a fluid temperature of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for limitations.
  • Differential pressure
    ∆pmax 350 kPa
  • Closing pressure
    690 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Flow characteristic
    Equal-percentage characteristic
  • Permissible leakage
    Bubble-tight, leakage class A
  • Pipe connection
    Flange
  • V'nom [l/s]
    33.3
  • Adjustable flow rate
    25...100% V'nom

Techniczna karta katalogowa

Download (4.29MB)

Instrukcja montażu

Download (1007.6KB)

Techniczna karta katalogowa – EP..F2-25+KBAC

Download (4.26MB)

EU Declaration of Conformity – EP125F2-25+KBAC

Download (361.78KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust