Belimo R3040-S3 - 3-way changeover ball valve
Belimo R3040-S3 3-way changeover ball valve for closed water systems. DN 40, Rp 1 1/2" internal thread, PN 25 and Kvs 31 m³/h.
Designed for changeover and open/close control on the water side of ventilation and heating systems. Medium: water or water with max. 50% vol. glycol; medium temperature -10...120°C [14...248°F].
Belimo R3040-S3 – changeover ball valve
3-way valve with internal thread for closed water systems. Used for changeover and open/close control on the water side of ventilation and heating systems. The valve is operated by a rotary actuator with an open/close signal.
Key features
- DN 40; Rp 1 1/2" connection with internal thread in accordance with ISO 7-1; PN 25.
- Kvs 31 m³/h; flow through bypass B – AB: approx. 50% of the Kvs value.
- Medium: water or water with max. 50% vol. glycol; medium temperature -10...120°C [14...248°F].
- Maximum differential pressure Δpmax 1000 kPa; closing pressure ∆ps 1400 kPa. 200 kPa is specified for quiet operation.
- Tightness A – AB: bubble-tight, leakage rate class A (EN 12266-1); B – AB: leakage rate class I (EN 1349 and EN 60534-4), max. 1% of the Kvs value.
- Rotation angle 90°. Nickel-plated brass body; stainless steel closing element and stem.
Installation notes
Installation is permitted from vertical to horizontal relative to the axis; installation with the axis pointing downwards is not permitted. Observe the flow direction indicated by the arrow on the body.
For medium temperatures of -10...2°C, stem heating or an extended valve neck is recommended. The permitted medium temperature may depend on the actuator type; limits are specified in the actuator data sheets.
-
Brand
-
ReferenceR3040-S3
-
EAN137630498107863
-
Kvs31 m³/h
-
MediumWater, water with up to 50% vol. glycol.
-
Pattern3-way
-
Fluid temperature-10...120°C [14...248°F]
-
Fluid temperature, noteFor medium temperatures of -10...2°C, heating the shaft or extending the valve neck is recommended. The permissible medium temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for restrictions.
-
Differential pressure∆pmax 1000 kPa
-
Closing pressure1400 kPa
-
Differential pressure note200 kPa for quiet operation
-
Permissible leakageA – AB: bubble-tight, leakage class A; B – AB: leakage class I, max. 1% of Kvs value
-
Pipe connectionInternal thread