Belimo R3050-S4 - 3-way changeover ball valve

Price: zł1,293.89
VAT included
zł1,051.94 tax excluded

Belimo R3050-S4 is a 3-way changeover ball valve DN 50 with Rp 2" female thread, PN 25 and Kvs 49 m³/h. Designed for closed water systems, for changeover and open/close control on the water side of ventilation and heating systems.

Product availability: Delivery in approx. 14 days
Share

Belimo R3050-S4 – technical data

3-way changeover ball valve for water and water with up to 50% vol. glycol. The valve is moved by a rotary actuator controlled by an open/close signal.

  • Nominal diameter: DN 50; connection: Rp 2" female thread in accordance with ISO 7-1; PN 25.
  • Kvs: 49 m³/h; flow through bypass B – AB: approx. 50% of the Kvs value.
  • Medium temperature: -10...120°C [14...248°F].
  • Maximum differential pressure Δpmax: 1000 kPa; closing pressure ∆ps: 1400 kPa. 200 kPa is specified for quiet operation.
  • Leakage A – AB: bubble-tight, leakage class A; B – AB: leakage class I, max. 1% of the Kvs value.
  • Angle of rotation: 90°. Nickel-plated brass body; stainless steel closing element and shaft.
  • Permitted mounting position: from vertical to horizontal relative to the axis; installation with the axis pointing downwards is not permitted.

At a medium temperature of -10...2°C, shaft heating or a valve neck extension is recommended. The permitted temperature range may depend on the actuator type; limitations are given in its data sheet.

  • Brand
  • Reference
    R3050-S4
  • EAN13
    7630498107924

  • Kvs
    49 m³/h
  • Medium
    Water, water with up to 50% vol. glycol.
  • Pattern
    3-way
  • Fluid temperature
    -10...120°C [14...248°F]
  • Fluid temperature, note
    For medium temperatures of -10...2°C, heating the shaft or extending the valve neck is recommended. The permissible medium temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for restrictions.
  • Differential pressure
    ∆pmax 1000 kPa
  • Closing pressure
    1400 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Permissible leakage
    A – AB: bubble-tight, leakage class A; B – AB: leakage class I, max. 1% of Kvs value
  • Pipe connection
    Internal thread

Techniczna karta katalogowa

Download (1.02MB)

Instrukcja montażu

Download (544.36KB)

Techniczna karta katalogowa – R3..-S..

Download (1.03MB)

EU Declaration of Conformity – R2050.. / R3050.. DN 50

Download (80.36KB)

Environmental Declaration – R3..

Download (70.29KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support