Belimo R515 - 3-way changeover ball valve

Price: zł606.73
VAT included
zł493.28 tax excluded

Belimo R515 is a DN 15 3-way changeover ball valve with G 1" male thread. Specifications: PN 40, Kvs 8.6 m³/h, ps 1600 kPa and medium temperature -10...100°C [14...212°F].

Product availability: Delivery in approx. 14 days
Share

Belimo R515 – changeover ball valve

3-way ball valve with male thread, designed for changeover and on/off control on the water side of ventilation and heating systems. It can be used in open and closed water systems.

Key specifications

  • DN 15; G 1" male threaded connection in accordance with ISO 228-1; PN 40.
  • Kvs 8.6 m³/h; ps 1600 kPa; closing pressure ∆ps 1400 kPa; maximum differential pressure ∆pmax 400 kPa.
  • Medium: water or water with a maximum of 50% by volume glycol; drinking water on request.
  • Medium temperature: -10...100°C [14...212°F].
  • Bypass B – AB: flow approx. 50% of the Kvs value.
  • Tightness: A – AB bubble-tight, leakage rate class A (EN 12266-1); B – AB leakage rate class I (EN 1349 and EN 60534-4), max. 1% of the Kvs value.
  • Nickel-plated brass body; stainless steel closing element and stem. Rotation angle: 90°.

Installation and operating instructions

Permitted installation position: from vertical to horizontal in relation to the stem; installation with the stem pointing downwards is not permitted. At a medium temperature of -10...2°C, a valve neck extension is recommended. The permitted medium temperature may depend on the actuator type; limitations are specified in the actuator data sheets. A differential pressure of 200 kPa is specified for quiet operation.

  • Brand
  • Reference
    R515
  • EAN13
    7630498108358

  • Kvs
    8.6 m³/h
  • Medium
    Water, water with up to 50% vol. glycol.
  • Pattern
    3-way
  • Fluid temperature
    -10...100°C [14...212°F]
  • Fluid temperature, note
    At a fluid temperature of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for limitations.
  • Differential pressure
    ∆pmax 400 kPa
  • Closing pressure
    1400 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Permissible leakage
    A – AB: bubble-tight, leakage class A; B – AB: leakage class I, max. 1% of Kvs value
  • Pipe connection
    External thread

Techniczna karta katalogowa

Download (721.78KB)

Instrukcja montażu

Download (556.22KB)

Techniczna karta katalogowa – R5.. changeover

Download (723.03KB)

EU Declaration of Conformity – R5.. / R4.. DN 15...50

Download (55.18KB)

Environmental Declaration – R5..

Download (70.42KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...
Back to top