Belimo R532 - 3-way changeover ball valve

Price: zł1,233.71
VAT included
zł1,003.02 tax excluded

Belimo R532 is a 3-way changeover ball valve DN 32 with G 2" male thread. Parameters: PN 25, ps 1600 kPa, Kvs 32 m³/h. Fluid temperature: -10...100°C [14...212°F].

Product availability: Delivery in approx. 14 days
Share

Belimo R532 – changeover ball valve

3-way valve with male thread for changeover and open/close control on the water side of ventilation and heating systems. Designed for open and closed water systems.

Key features

  • DN 32; G 2" male threaded connection; PN 25; ps 1600 kPa.
  • Kvs 32 m³/h; flow through bypass B – AB: approximately 50% of the Kvs value.
  • Fluid: water and water with a maximum of 50% by volume glycol; drinking water on request.
  • Fluid temperature: -10...100°C [14...212°F].
  • Maximum differential pressure ∆pmax 400 kPa; closing pressure ∆ps 1400 kPa. 200 kPa is specified for quiet operation.
  • Tightness A – AB: air-bubble-tight, leakage rate class A; B – AB: leakage rate class I, max. 1% of the Kvs value.
  • Nickel-plated brass body; stainless steel closing element and stem.
  • Rotation angle: 90°.

Installation notes

Permitted installation from vertical to horizontal in relation to the stem; do not install with the stem pointing downwards. Observe the flow direction indicated by the arrow on the body.

For fluid temperatures of -10...2°C, a valve neck extension is recommended. The permitted fluid temperature may depend on the actuator type; limitations are specified in the actuator data sheets.

  • Brand
  • Reference
    R532
  • EAN13
    7630498108457

  • Kvs
    32 m³/h
  • Medium
    Water, water with up to 50% vol. glycol.
  • Pattern
    3-way
  • Fluid temperature
    -10...100°C [14...212°F]
  • Fluid temperature, note
    At a fluid temperature of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for limitations.
  • Differential pressure
    ∆pmax 400 kPa
  • Closing pressure
    1400 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Permissible leakage
    A – AB: bubble-tight, leakage class A; B – AB: leakage class I, max. 1% of Kvs value
  • Pipe connection
    External thread

Techniczna karta katalogowa

Download (721.78KB)

Instrukcja montażu

Download (556.22KB)

Techniczna karta katalogowa – R5.. changeover

Download (723.03KB)

EU Declaration of Conformity – R5.. / R4.. DN 15...50

Download (55.18KB)

Environmental Declaration – R5..

Download (70.42KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...