Belimo EV050R2+BAC - 2-way Energy Valve control valve DN 50
Belimo EV050R2+BAC is a 2-way Energy Valve control valve DN 50, PN 25, with thermal energy measurement and control of flow, power or differential pressure. V'nom is 4.17 l/s, and V'max can be set within 25...100% V'nom.
Supply AC/DC 24 V; communication: BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud. Internal and external threaded connections: Rp 2", G 2 1/2".
Belimo EV050R2+BAC – Energy Valve DN 50
2-way PI-CCV control valve for closed water systems. Combines a valve with an actuator, a flow sensor and thermal energy measurement. Enables control of flow, power, position and differential pressure; the latter mode requires a differential pressure sensor, which is not included in the scope of delivery.
Key features and parameters
- DN 50, PN 25; internal and external threads Rp 2", G 2 1/2".
- V'nom 4.17 l/s (15 m³/h); V'max adjustable from 25...100% V'nom.
- Medium: water or water with a maximum of 60% vol. glycol; medium temperature -10...120°C [14...248°F].
- ∆pmax 350 kPa; closing pressure ∆ps 1400 kPa.
- Supply AC/DC 24 V; power consumption during operation 5 W, in standby 3.9 W; power rating for cable sizing 7.5 VA.
- Control signal Y 2...10 V; modulating, communicative or hybrid control.
- Communication: BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud. RJ45 Ethernet socket and integrated web server.
- Ultrasonic flow measurement, monitoring of power and energy and glycol concentration; data logging for 13 months.
- Integrated delta T manager; not available in differential pressure control mode.
- NFC interface for configuration using Belimo Assistant 2; manual adjustment by button, with the option to lock it.
- Degree of protection IEC/EN IP54; protection class IEC/EN III, Protective Extra-Low Voltage (PELV).
An insulation shell for DN 32...50 is provided; according to the documentation, it is not supplied in the Asia-Pacific region.
-
Brand
-
ReferenceEV050R2+BAC
-
EAN137630498111396
-
MediumWater, water with max. 60% vol. glycol.
-
Pattern2-way
-
Fluid temperature-10...120°C [14...248°F]
-
Fluid temperature, noteAt a medium temperature of -10...2°C, heating the shaft or extending the valve neck is recommended.
-
Differential pressure∆pmax 350 kPa
-
Closing pressure1400 kPa
-
Differential pressure note200 kPa for quiet operation
-
Flow characteristicEqual-percentage characteristic
-
Permissible leakageBubble-tight, leakage class A
-
Pipe connectionInternal and external thread
-
V'nom [l/s]4.17
-
Adjustable flow rate25...100% V'nom
Over 20 years of experience
Reliable service and customer trust
Help with selecting and operating equipment