Belimo EP100F2-16+BAC - 2-way EPIV control valve

Price: zł31,555.65
VAT included
zł25,655.00 tax excluded

2-way EPIV control valve with pressure-independent flow and flow measurement-based control. DN 100 version, PN 16, with flanged connection and V'nom 20.8 l/s (75 m³/h).

AC/DC 24 V supply; BACnet MS/TP, Modbus RTU and MP-Bus communication. Supports glycol concentration monitoring and configuration via NFC using Belimo Assistant 2.

Product availability: Product unavailable
Share

Notify me when available

Interested in this product? Drop us an email and we will let you know when it's available for order.

Belimo EP100F2-16+BAC – EPIV control valve

2-way control valve with sensor-based flow control, designed for closed water systems. Enables modulating control of water circuits in ventilation and heating systems.

Key features and specifications

  • Nominal diameter DN 100, nominal pressure PN 16 and flanged connection.
  • Nominal flow V'nom 20.8 l/s (75 m³/h); V'max setting range 25...100% V'nom.
  • AC/DC 24 V supply; power consumption 5.1 W in operation and 2.6 W in standby position.
  • Modulating, communicative or hybrid control; Y operating range 2...10 V and BACnet MS/TP, Modbus RTU and MP-Bus communication.
  • Ultrasonic flow measurement, fluid temperature measurement and glycol concentration monitoring.
  • Fluid: water or water with up to 60% vol. glycol; fluid temperature -10...120°C [14...248°F].
  • Maximum differential pressure ∆pmax 350 kPa; closing pressure ∆ps 690 kPa.
  • NFC interface for configuration using Belimo Assistant 2; manual adjustment by push-button, with the option to lock it.
  • Electrical connection: 1 m cable, 6x 0.75 mm²; IP54 protection rating.

At fluid temperatures of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may depend on the actuator type.

  • Brand
  • Reference
    EP100F2-16+BAC
  • EAN13
    7630498136856

  • Medium
    Water, water with max. 60% vol. glycol.
  • Pattern
    2-way
  • Fluid temperature
    -10...120°C [14...248°F]
  • Fluid temperature, note
    At a fluid temperature of -10...2°C, extending the valve neck is recommended. The permissible fluid temperature may be limited depending on the actuator type. Refer to the relevant actuator data sheets for limitations.
  • Differential pressure
    ∆pmax 350 kPa
  • Closing pressure
    690 kPa
  • Differential pressure note
    200 kPa for quiet operation
  • Flow characteristic
    Equal-percentage characteristic
  • Permissible leakage
    Bubble-tight, leakage class A
  • Pipe connection
    Flange
  • V'nom [l/s]
    20.8
  • Adjustable flow rate
    25...100% V'nom

Techniczna karta katalogowa

Download (3.95MB)

Instrukcja montażu

Download (979.51KB)

Techniczna karta katalogowa – EP..F2-16+BAC

Download (3.96MB)

EU Declaration of Conformity – EP100F2-16+BAC

Download (361.78KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...
Back to top