Belimo 22PE-1UH - thermal energy meter

Price: zł4,785.39
VAT included
zł3,890.56 tax excluded

Belimo 22PE-1UH thermal energy meter for measuring energy in a closed heating or cooling circuit. It uses ultrasonic flow measurement and automatic glycol content compensation. Connection parameters: DN 50, G 2 1/2" male thread, PN 25; nominal flow qp 15 m³/h.

Power supply AC/DC 24 V or PoE. Communication: BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus and Cloud; M-Bus is available via a converter. Configuration via Belimo Assistant 2 or the integrated web server.

Product availability: Delivery in approx. 14 days
Share

Belimo 22PE-1UH – thermal energy meter

The device measures thermal energy in a closed heating or cooling circuit based on volumetric flow and temperature difference. It can operate as a heat meter, cooling meter or combined heating and cooling meter. The flow sensor can be installed in the supply or return pipe; the installation position is selected during commissioning.

Key features

  • Ultrasonic flow measurement; measured values: flow and temperature.
  • DN 50, G 2 1/2" male thread in accordance with ISO 228-1, PN 25.
  • Nominal flow qp 15 m³/h, maximum qs 30 m³/h and minimum qi 0.15 m³/h.
  • Medium: water or water with a maximum of 60% vol. glycol; automatic measurement and compensation of glycol content.
  • Power supply AC/DC 24 V; PoE power supply option.
  • Communication: BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus, Cloud; M-Bus via G-22PEM-A01 converter.
  • Voltage output: 1 x 0...10 V, 0.5...10 V, 2...10 V.
  • Configuration via Belimo Assistant 2 or the integrated web server; NFC interface.
  • Degree of protection of sensor module: IP65; logic module: IP54 with A-22PEM-A04 cable gland.

An insulation shell for DN 32...50 is included; according to the technical data sheet, the insulation shell is not included in the Asia-Pacific region.

  • Brand
  • Reference
    22PE-1UH
  • EAN13
    7630498110344

  • Electrical connection
    Cable
  • Measured values
    Flow Temperature
  • Output signal
    BACnet Modbus MP-Bus 0...10 V
  • AC/DC voltage
    AC/DC 24 V
  • Output voltage range [Range]
    1 x 0...10 V, 0.5...10 V, 2...10 V
  • Communication
    BACnet/IP BACnet MS/TP Modbus TCP Modbus RTU MP-Bus Cloud
  • Flow qp
    15
  • Medium
    Water, water with max. 60% vol. glycol.
  • Valve size
    50 mm | 2 inch

Techniczna karta katalogowa

Download (5.69MB)

Instrukcja montażu

Download (1.37MB)

Techniczna karta katalogowa – 22PE-1U..

Download (5.12MB)

EU Declaration of Conformity – 22PE-1UH

Download (344.19KB)

Environmental Declaration – 22PE..

Download (71.71KB)
In business since 2005
Over 20 years of experience
A trusted partner
Reliable service and customer trust
Technical support
Help with selecting and operating equipment

You might also like

Comments (0)

No customer reviews for the moment.

4 other products in the same category

Loading...
Back to top