Belimo EV040R2+MID is a 2-way Energy Valve™ control valve with a thermal energy meter, certified for heating applications in accordance with MID / EN 1434. It enables flow or power control based on measurements and monitoring of power and energy.
DN 40, PN 25, Rp 1 1/2" and G 2" connections, V'nom 2.78 l/s. AC/DC 24 V supply; BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus and Cloud communication.
Belimo EV040R2+MID – Energy Valve™ with thermal energy meter
2-way control valve with actuator, flow and temperature measurement, and power and energy monitoring. Designed for closed water systems and water-side control in ventilation and heating installations. The thermal energy meter is MID-approved and meets EN 1434 requirements for heating applications.
Key features and specifications
- Size DN 40, PN 25; Rp 1 1/2" internal thread and G 2" external thread.
- Nominal flow V'nom 2.78 l/s; adjustable V'max in the range 25...100% V'nom.
- Control by flow, power, position or differential pressure. Differential pressure control requires a suitable sensor, which is not included.
- Power and energy monitoring, glycol concentration monitoring, and data logging for 13 months.
- Integrated delta T manager; available in power, flow and position control modes.
- BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus and Cloud communication; also features an integrated web server and NFC interface for configuration with Belimo Assistant 2.
- AC/DC 24 V supply; power consumption 5 W during operation and 3.9 W in the rest position; wire sizing power 7.5 VA.
- Control signal Y range 2...10 V. Manual override by push-button, with the option to lock it.
- Medium: water; medium temperature -10...120°C [14...248°F]. MID-certified medium temperature range: 15...120°C.
- ∆pmax 350 kPa; closing pressure ∆ps 1400 kPa.
- IEC/EN IP54 protection rating; IEC/EN protection class III, Protective Extra-Low Voltage (PELV).
- Insulation shell for DN 32...50 included; according to the datasheet, the shell is not included in the Asia-Pacific region.
For medium temperatures of -10...2°C, the manufacturer recommends stem heating or a valve neck extension.
-
Brand
-
ReferenceEV040R2+MID
-
EAN137630498111372
-
MediumWater
-
Pattern2-way
-
Fluid temperature-10...120°C [14...248°F]
-
Fluid temperature, noteMID certificate 15...120°C. At a fluid temperature of -10...2°C, heating the stem or extending the valve neck is recommended.
-
Differential pressure∆pmax 350 kPa
-
Closing pressure1400 kPa
-
Differential pressure note200 kPa for quiet operation
-
Flow characteristicEqual-percentage characteristic
-
Permissible leakageBubble-tight, leakage class A
-
Pipe connectionInternal and external thread
-
V'nom [l/s]2.78
-
Adjustable flow rate25...100% V'nom