Belimo EV050R2+MID - DN 50 2-way Energy Valve control valve
Belimo EV050R2+MID is a 2-way Energy Valve control valve with a thermal energy meter, certified for heating applications in accordance with MID and compliant with EN 1434. The DN 50, PN 25 model has Rp 2" internal and G 2 1/2" external threaded connections and a nominal flow rate V'nom 4.17 l/s.
The valve enables flow or power control based on sensor measurements and monitoring of power and energy. It supports BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus and Cloud.
Belimo EV050R2+MID – Energy Valve with thermal energy meter
2-way control valve with actuator, flow sensor and temperature sensors, designed for closed water systems and modulating control of air-conditioning and heating systems on the water side. The thermal energy meter has MID approval for heating applications and complies with EN 1434.
Key features
- DN 50, PN 25; Rp 2" internal and G 2 1/2" external threads.
- Nominal flow rate V'nom 4.17 l/s; adjustable V'max 25...100% of V'nom.
- Flow, power and position control; differential pressure control requires a sensor, which is not included.
- Ultrasonic flow measurement and monitoring of power, energy and glycol concentration.
- AC/DC 24 V supply; power consumption during operation 5 W, in standby position 3.9 W; cable sizing power 7.5 VA.
- Control signal 2...10 V; communication via BACnet/IP, BACnet MS/TP, Modbus TCP, Modbus RTU, MP-Bus and Cloud.
- NFC interface, integrated web server, delta T manager and data logging for 13 months.
- Medium: water; medium temperature -10...120°C [14...248°F], with MID certification covering 15...120°C.
- Differential pressure ∆pmax 350 kPa; closing pressure ∆ps 1400 kPa.
- IP54 protection rating; manual adjustment by push-button with locking option.
An insulation shell for DN 32...50 is included; according to the documentation, it is not included in the Asia-Pacific region.
-
Brand
-
ReferenceEV050R2+MID
-
EAN137630498111419
-
MediumWater
-
Pattern2-way
-
Fluid temperature-10...120°C [14...248°F]
-
Fluid temperature, noteMID certificate 15...120°C. At a fluid temperature of -10...2°C, heating the stem or extending the valve neck is recommended.
-
Differential pressure∆pmax 350 kPa
-
Closing pressure1400 kPa
-
Differential pressure note200 kPa for quiet operation
-
Flow characteristicEqual-percentage characteristic
-
Permissible leakageBubble-tight, leakage class A
-
Pipe connectionInternal and external thread
-
V'nom [l/s]4.17
-
Adjustable flow rate25...100% V'nom
Over 20 years of experience
Reliable service and customer trust
Help with selecting and operating equipment